Cementitious
Explore our Products
PRECISION & ULTRA HIGH EARLY STRENGTH
DESIGNATION
DESCRIPTION
PRINCIPLE USES
COVERAGE / YIELD
TDS
CONGROUT FR
A precision non shrink cementitious grout with corrosion & fire resistance properties.
Used under machine base plates, bridge bearings and all areas requiring precision grouting with corrosion & fire resistance.
76 x 25 kg bags & 285 litres of water for approx. 1m3 of mortar.
CONGROUT 1000
Non shrink, pre-mixed, cementitious fine precision grout for gaps down to 5 mm.
For grouting narrow gaps under machine base plates, columns, crane rails, bridge bearings etc.
75 x 25 kg bags for approx. 1m3 of grout depending on water content.
CONGROUT RES
Very rapid early strength, non shrink cementitious precision grout.
For use where early loading is required, 25 N/mm2 at approx. 2 hours. 40-50 N/mm2 at 6-8 hours.
74-75 x 25 kg bags +294 ltr of water for approx. 1m3 of grout for fluid consistency.
72-74 x 25 kg bags +243.6 ltr of water for approx. 1m3 of grout for pourable consistency.
CONGROUT AF
A ready to use high strength premixed, flowing, non shrink cable grout. Expansion/no shrinkage ensures good interfacial contact is maintained.
Use for the grouting of prestressed cable ducts, bearing plates, tunnel linings, rock & soil anchoring etc.
Approx 74-75 bag x 20 kg for approx 1m3 grout depending on water content.
WIND TURBINE
DESIGNATION
DESCRIPTION
PRINCIPLE USES
COVERAGE / YIELD
TDS
CONGROUT WT
A cement based shrinkage compensated ultra high strength grount produced using latest nano molecular,polymer and fibre technology. When mixed with water it produces a homogeneous high flow, high strength grout.
Use for the grouting of wind turbine baseplates,or other precision grouting applications and anchors using pre stressing techniques which may be pumped or poured into place.
2,400 kg /m3
GENERAL PURPOSE
DESIGNATION
DESCRIPTION
PRINCIPLE USES
COVERAGE / YIELD
TDS
CONGROUT GP
Economical non shrink, premixed cementitious grout for non critical applications.
Economical grout for minor concrete repairs and patching, grouting, filling core holes and defects in concrete.
74-76 x 25 kg bags for approx. 1m3 of grout depending on water content.
CONGROUT PADDING MORTAR
Ready to use cementitious padding mortar for use before grouting.
Bedding & leveling machine bases before grouting.
See data sheet.
UNDER WATER
DESIGNATION
DESCRIPTION
PRINCIPLE USES
COVERAGE / YIELD
TDS
CONGROUT UWG
A non shrink cement based grout for underwater applications.
Designed for use in underwater or tidal zones such as bridge & quay columns, concrete piling, slipways, dams & other underwater structures.
Approx. 69-70 bag x 25 kg for approx 1m3 grout depending on water content.
GROUT ADDITIVES
DESIGNATION
DESCRIPTION
PRINCIPLE USES
COVERAGE / YIELD
TDS
CONGROUT A
A ready to use cement grout admixture.
Expanding grout admixture for specialist grouting of cable ducts, tunnel linings etc.
1-2% by weight of cement.
CONGROUT ADMIX
Powder admixture for use in cementitious grouts. Provides flow, no bleeding or shrinkage.
For producing non shrink grout on site.
0.5-2% by weight of cement.
Cementitious
PRECISION & HIGH EARLY STRENGTH
DESIGNATION : CONGROUT FR
DESCRIPTION : A precision non shrink cementitious grout with corrosion & fire resistance properties.
PRINCIPLE USES : Used under machine base plates, bridge bearings and all areas requiring precision grouting with corrosion & fire resistance.
COVERAGE / YIELD : 76 x 25 kg bags & 285 litres of water for approx. 1 m3 of mortar.
DESIGNATION : CONGROUT 1000
DESCRIPTION : Non shrink, pre-mixed, cementitious fine precision grout for gaps down to 5 mm.
PRINCIPLE USES : For grouting narrow gaps under machine base plates, columns, crane rails, bridge bearings etc.
COVERAGE / YIELD : 75 x 25 kg bags for approx. 1 m3 of grout depending on water content.
DESIGNATION : CONGROUT RES
DESCRIPTION : Very rapid early strength, non shrink cementitious precision grout.
PRINCIPLE USES : For use where early loading is required, 25 N/mm2 at approx. 2 hours. 40-50 N/mm2 at 6-8 hours.
COVERAGE / YIELD : 74-75 x 25 kg bags +294 ltr of water for approx. 1m3 of grout for fluid consistency.
72-74 x 25 kg bags +243.6 ltr of water for approx. 1 m3 of grout for pourable consistency.
DESIGNATION : CONGROUT AF
DESCRIPTION : A ready to use high strength premixed, flowing, non shrink cable grout. Expansion/no shrinkage ensures good interfacial contact is maintained.
PRINCIPLE USES : Use for the grouting of prestressed cable ducts, bearing plates, tunnel linings, rock & soil anchoring etc.
COVERAGE / YIELD : Approx 74-75 bag x 20 kg for approx 1 m3 grout depending on water content.
GENERAL PURPOSE
DESIGNATION : CONGROUT GP
DESCRIPTION : Economical non shrink, premixed cementitious grout for non critical applications.
PRINCIPLE USES : Economical grout for minor concrete repairs and patching, grouting, filling core holes and defects in concrete.
COVERAGE / YIELD : 74-76 x 25 kg bags for approx. 1 m3 of grout depending on water content.
DESIGNATION : CONGROUT PADDING MORTAR
DESCRIPTION : Ready to use cementitious padding mortar for use before grouting.
PRINCIPLE USES : Bedding & leveling machine bases before grouting.
COVERAGE / YIELD : See data sheet.
UNDER WATER
DESIGNATION : CONGROUT UWG
DESCRIPTION : A non shrink cement based grout for underwater applications.
PRINCIPLE USES : Designed for use in underwater or tidal zones such as bridge & quay columns, concrete piling, slipways, dams & other underwater structures.
COVERAGE / YIELD :Approx. 69-70 bag x 25 kg for approx 1 m3 grout depending on water content.
GROUT ADDITIVES
DESIGNATION : CONGROUT A
DESCRIPTION : A ready to use cement grout admixture.
PRINCIPLE USES : Expanding grout admixture for specialist grouting of cable ducts, tunnel linings etc.
COVERAGE / YIELD : 1-2% by weight of cement.
DESIGNATION : CONGROUT ADMIX
DESCRIPTION : Powder admixture for use in cementitious grouts. Provides flow, no bleeding and no shrinkage.
PRINCIPLE USES : For producing non shrink grout on site.
COVERAGE / YIELD : 0.5-2% by weight of cement.